Inline
Applications: Water, Oil, High Accuracy, Wide Range.Fluids: Liquid or gas
Size: ½ to 12 inches
Range: 0.001 to 15,000 GPM (liquid) or 0.001 to 15,000 ACFM (gas)
Accuracy: ±0.3% to ±0.5% of reading
Pressure: Max 5000 psi
Temperature: -430 to 750 °F
Pickups: Magnetic (30mV), modulated carrier (5 or 10 V)
Response: 3 to 25 ms
Power: None, 12 or 24 VDC
Outputs: Rate: 4-20 mA, pulse, hi/lo switch
Materials: Body: 316 stainless steel, other materials available
Bearings: 440C SS, tungsten carbide, ceramic